MTT 10 MF38 – 3.07 Let the furnace heat up at its maximum rate to 900°C without interruption, and then soak for 1 hour. Fumes may be emitted: th
MTT MF38 – 3.07 11 6.0 FAULT ANALYSIS A. Furnace Does Not Heat Up 1. The HEAT light is ON The heating element has failed Check also t
MTT 12 MF38 – 3.07 7.0 CIRCUIT DIAGRAMS 7.1 MTT – Single Phase Instrument Switch coil temperature controller thermocouple overtemp. controll
MTT MF38 – 3.07 13 8.0 FUSES & POWER SETTINGS 8.1 Fuses Supply fuses (F1 in circuit diagram) - 12.5A glass type F 32mm x 6mm Control
MTT 14 MF38 – 3.07 9.0 SPECIFICATIONS Carbolite reserves the right to change specifications without notice. 9.1 Models Covered by this Manual
MTT MF38 – 3.07 15
Carbolite, Parsons Lane, Hope, Hope Valley, S33 6RB, England. Telephone: +44 (0)1433 620011 Fax: +44 (0)1433 621198 E-mail: [email protected] The p
MTT 2 MF38 – 3.07 1.0 SYMBOLS & WARNINGS 1.1 Switches and Lights 1.2 Warning Symbols Instrument switch: when the instru
MTT MF38 – 3.07 3 2.0 INSTALLATION 2.1 Unpacking & Handling When unpacking or moving the furnace always lift it by its base or by both end
MTT 4 MF38 – 3.07 2.3 Connection to a Computer This furnace is normally fitted with RS485 3-wire communications on the main controller only. For
MTT MF38 – 3.07 5 3.0 OPERATION 3.1 “MTT 12/38/850” – two zone combustion tube furnace. The furnace is based on the Carbolite model MTF 12/38/
MTT 6 MF38 – 3.07 3.3 General Operating Advice Heating element life is shortened by use at temperatures close to maximum. Do not leave the furn
MTT MF38 – 3.07 7 4.0 MAINTENANCE 4.1 General Maintenance No routine maintenance is required. The outer surfaces may be cleaned with a damp cl
MTT 8 MF38 – 3.07 5.0 REPAIRS & REPLACEMENTS 5.1 Safety Warning – Disconnection from Supply Always ensure that the furnace is disconnected
MTT MF38 – 3.07 9 5.5 Thermocouple Replacement Disconnect the furnace from the supply. It is necessary to separate the furnace from its base